Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Gen Dent ; 58(4): e168-71, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20591765

RESUMO

An implant-retained overdenture is less expensive than a fixed implant-retained prosthesis; however, using ball attachments on abutments that are nonparallel and/or outside the path of insertion may result in loss of retention. As described in this case report, alignment devices can be used as a mandibular overdenture retainer to diminish the lack of parallelism between two implants. The treatment plan involved the use of an alignment device on each implant to ensure correct alignment among ball attachments and its retentive component. These devices can be used to fabricate overdentures retained by implants that are misaligned by as much as 14 degrees.


Assuntos
Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante/instrumentação , Prótese Total Inferior , Revestimento de Dentadura , Arcada Edêntula/reabilitação , Adulto , Dente Suporte , Implantação Dentária Endóssea/instrumentação , Implantação Dentária Endóssea/métodos , Implantes Dentários , Retenção de Dentadura , Humanos , Masculino , Mandíbula , Resultado do Tratamento
2.
Braz. j. oral sci ; 9(2): 89-93, Apr.-June 2010. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-578071

RESUMO

Aim: Mechanical characteristics of the preparation along with luting agent are significant elements on the maintenance of fixed prostheses. This study aimed at assessing the retention of metal complete crowns luted with two different luting agents under different preparation height. Methods: Forty human third molars were selected and prepared to receive total crowns, and were randomly divided in 4 groups: (1) 5-mm preparation height (PH) and RelyX U100 self-adhesive resin cement (SA); (2) 5-mm PH and zinc phosphate (ZP); (3) 3-mm PH and SA; and (4) 3-mm PH and ZP. Crowns were cast in nickel-chromium alloy. The tensile strength was tested in a universal testing machine. Results: Mean tensile strength values to crown displacement (kgf) and standard deviation were 39.6 (13.0) for group 1; 16.9 (8.1) for group 2; 32.2 (7.9) for group 3; and 10.6(3.2) for group 4. Overall, the crowns cemented with SA presented significantly higher mean tensile strength values than ZP, and the 5-mm PH presented significantly higher mean tensile strength values than 3-mm PH. Conclusions: The self-adhesive resin cement and higher preparation height improved crown retention.


Assuntos
Humanos , Coroas , Cimentação/métodos , Cimentos de Resina , Retenção em Prótese Dentária/métodos , Resistência à Tração , Análise de Variância
3.
Full dent. sci ; 1(3): 242-247, abr.-jun. 2010. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-642946

RESUMO

Um dos erros mais frequentes em reabilitação oral é a montagem incorreta dos modelos de gesso no articulador. Os modelos de estudo e, principalmente, os modelos de trabalho, devem ser rigorosamente posicionados numa relação funcional no articulador, que irá representar a maxila e a mandíbula com a articulação temporomandibular e os movimentos mandibulares. O objetivo deste trabalho foi avaliar através de um estudo laboratorial a precisão do articulador A7 Fix Bio-Art padronizado, quando simuladores dos modelos são transferidos de um articulador para outro. Para a realização desta pesquisa foram selecionados dez articuladores e desses, um foi designado como articulador mestre. Foram confeccionadas peças que representassem as duas arcadas e essas foram montadas no articulador mestre e transferidos para os outros nove articuladores e avaliado na transferência os seguintes critérios: efetividade do contato com o carbono (avaliação vertical), coincidência dos parafusos com os orifícios (avaliação horizontal), e coincidência do pino incisal com a linha cheia (avaliação vertical). Os resultados encontrados foram de que em todas as transferências os três parafusos do modelo superior coincidiram com as concavidades realizadas no modelo inferior; a relação de contato interoclusal permaneceu em todas as transferências; somente em dois articuladores houve 1 mm de discrepância em relação a linha cheia. Conclui-se que o articulador A7 Fix (Bio-Art) padronizado permitiu o intercâmbio dos modelos de gesso entre os articuladores.


One of the most usual mistakes in oral rehabilitation is the incorrect assemblage of the cast models on the articulating device. The study models and mainly the work models must be strictly placed to a functional relation on the articulator, which will represent the maxilla and the mandible, with the temporomandibular articulation and the mandible movements. This work aims at evaluating, through a laboratorial experimental study, the accuracy of the 7 Fix Bio-Art standardized when the simulators of the models are transferred from one articulator to another. Ten articulators were selected for this study and one of them was chosen as the master articulator. Parts representing the two articulators were manufactured and assembled on the master articulator and transferred to other nine articulators and in the transference the following criterion were evaluated: effectiveness of the contact with the carbon (vertical evaluation), coincidence of the screws with the holes (horizontal evaluation), and coincidence of the incisal pin with the full line (vertical evaluation) the results found at the end of the test were: in all transference of the three screws of the superior model fit the concavities in the inferior model; the relation of the interoclusal contact happened in the proper way in all transference; only in two of the articulators there was a difference of 1 mm in relation to the full line. It was concluded that the standardization of the A7 FIX (Bio-Art) allowed the interchange of the models among the articulators’ devices.


Assuntos
Articuladores Dentários , Estética Dentária , Registro da Relação Maxilomandibular , Reabilitação Bucal , Prótese Dentária/instrumentação
4.
ImplantNews ; 7(4): 465-470, 2010. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-564682

RESUMO

A reabilitação oral de pacientes edentados totais inferiores através de implantes com carga imediata tem se tornado um procedimento seguro e de alta previsibilidade. Entretanto, a reabilitação de maxilas edêntulas continua sendo um dos procedimentos mais complexos da Implantodontia. O objetivo deste trabalho foi analisar a efetividade de implantes utilizados em reabilitação total superior submetida à carga imediata. Foram selecionados estudos clínicos de indivíduos que se submeteram a uma reabilitação total superior implanto-suportada com carga imediata. Os estudos foram analisados a partir de itens estabelecidos e, posteriormente, os dados obtidos foram transcritos para uma tabela que serviu de base para a análise dos resultados. A taxa de sucesso dos implantes foi medida segundo o tempo de acompanhamento do estudo e segundo o número de implantes por individuo. Segundo o tempo de acompanhamento, a taxa de sucesso foi de 98,5% quando acompanhados até dois anos e 96,5% quando acompanhados por um período de três a sete anos. Quanto ao número de implantes por individuo, a taxa de sucesso foi de 97,4% quando utilizados quatro implantes, 98,15% quando utilizados de cinco a sete implantes e 98,8% quando utilizados de oito a 12 implantes. Portanto, conclui-se que a taxa de sucesso dos implantes utilizados em protocolos totais superiores com carga imediata aumentou proporcionalmente ao número de implantes utilizados e diminuiu quanto maior for o tempo de acompanhamento do estudo.


The oral rehabilitation of total edentulous mandibular patients through immediate-loaded implants has become a safe procedure with a high predictability. However, the rehabilitation of edentulous maxilla is still one of the most complex procedures of dentistry. The objective of this study was to analyze the effectiveness of immediately loaded implants supporting fixed prostheses in the edentulous maxilla. The scientific articles had been analyzed through established item and later the screened data had been analyzed. The rate of success of the implants was measured according to time of follow- up of the study and according to the number of implants per individual. According to time follow-up, there was a success rate of 98.5% when followed for two years and 96.5% when followed for three to seven years. According to the number of implants per individual, the success rate was 97.4% when four implants were used, 98.15% when five to seven implants were used and 98.8% when eight to 12 implants were used. Therefore, it is concluded that the rate of success of implants used in total upper fixed protocols with immediate loading increases along with the number of implants used and decreases with the number of follow-up time intervals.


Assuntos
Humanos , Prótese Dentária Fixada por Implante , Prótese Total Imediata , Prótese Total Superior , Implantes Dentários
5.
Full dent. sci ; 1(1): 42-47, 2009.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-602571

RESUMO

A presente pesquisa teve por objetivo avaliar a capacidade de percepção da adaptação marginal à sondagem com dois tipos de instrumentos, executada por cirurgiões dentistas. Trata-se de um estudo exploratório descritivo realizado na clínica dos cursos da Unidade de Pós-graduação da Faculdade Ingá/Uningá-Passo Fundo/RS. Para coleta dos dados 44 profissionais de diversos cursos de pós-graduação deram seus pareceres a respeito de diferentes desajustes cervicais previamente confeccionados em uma coroa total metálica fundida sobre o primeiro molar inferior direito de um manequim, utilizando para o exame duas sondas exploradoras de marcas diferentes (Duflex® e Hu-Friedy®). A adaptação de todas as faces foi percebida corretamente por somente 9,0% (4) dos profissionais com a sonda Duflex® e 27,2% (12) com a sonda Hu-Friedy®, o que demonstra uma diferença clínica importante. A adaptação marginal satisfatória e o degrau positivo foram os términos mais facilmente identificáveis à  sondagem, enquanto o degrau negativo e o espaço cervical foram os desajustes mais difí­ceis de serem identificados corretamente pelos profissionais. A sonda Hu-Friedy® possibilitou maior precisão no diagnóstico das faces para todos os grupos de alunos pesquisados.


This investigation aimed at assessing dentist’s ability for marginal fit perception through probing with two types of instruments. This is a descriptive exploratory study developed at the clinics of Postgraduation Unit Ingá/Uningá-Passo Fundo/RS. For data collection, 44 professionals from several post-graduation courses gave their opinions on different marginal misfit, previously done in a cast metallic crown over the right inferior first molar of a manikin. For examination two exploratory probes of different brands (Duflex® and Hu-Friedy®) were used. Correct fit of all walls were observed by only 9.0% (4) of the professionals with Duflex® probe and 27.2% (12) with Hu-Friedy® one, which shows an important clinical difference. Satisfactory marginal fit and positive bend were the most easily terminus found through probing, while negative bend and cervical space were the most difficult misfits to be correctly observed by the professionals. Hu-Friedy® probe favored more precise diagnostic of the walls for all groups of the investigated students.


Assuntos
Humanos , Masculino , Feminino , Coroas , Adaptação Marginal Dentária , Materiais Dentários , Ajuste de Prótese
6.
RFO UPF ; 11(1): 56-60, 2006. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-457220

RESUMO

Este trabalho avaliou a resistência flexural de dois materiais adesivos empregados no preenchimento de estruturas radiculares fragilizadas associados a pino pré-fabricados de fibra de vidro. Foram confeccionados 44 corpos-de-prova (n=11) distribuídos em G1 - resina composta para núcleo de preenchimento (Enforce Core - Dentsply); G2 - Ionômero de vidro modificado por resina (Vitremer - 3M Espe); G3 - Resina composta para núcleo de preenchimento (Enforce Core) + Pino intra-radicular de fibra de vidro (Fibrekor Post System - Jeneric Pentron); G4 - Ionômero de vidro modificado por resina (Vitremer) + pino intra-radicular de fibra de vidro (Fibrekor Post System). Os corpos-de-prova foram confeccionados com dimensões de 3 x 3 x 15mm, sendo armazenados em água destilada por 24 horas a 37 C, até a realização dos ensaio de flexão de três pontos. Os dados obtidos (MPa) foram submetidos aos testes Anova e de Tukey. O grupo G1 (164,21 MPa) foi superior estatisticamente (p < 0,001) aos demais. Os grupos G2 (73,67 MPa) e G4 (66,90 MPa) foram estatisticamente semelhantes entre si e inferior aos demais. Assim, conclui-se que a resina composta Enforce Core foi superior ao ionômero de vidro modificado por resina Vitremer quando à resistencia flexural. A utilização do pino de fibra de vidro reduziu os valores de resistência flexural para os dois materiais testados


Assuntos
Humanos , Masculino , Feminino , Resinas Compostas , Pinos Dentários , Cimentos de Ionômeros de Vidro , Resistência à Tração
7.
Camaragibe, PE; s.n; 2006. 131 p. ilus, graf. (BR).
Tese em Português | LILACS, BBO - Odontologia | ID: lil-535440

RESUMO

Esse trabalho avaliou a magnitude e a distribuição das tensões de von Mises em modelos tridimensionais de incisivo central superior hígido e em modelos com fraturas coronárias restaurados com resina composta associada a diferentes pinos intraradiculares, utilizando o método dos elementos finitos. O modelo do dente hígido e estruturas de sustentação foram gerados utilizando-se dados da literatura. Sobre esse modelo foram realizados modificações para a criação do modelo representando a fratura coronária e restauração com resina composta...


Assuntos
Materiais Dentários , Pinos Dentários , Restauração Dentária Permanente , Fraturas dos Dentes
8.
Rev. Fac. Odontol. Porto Alegre ; 45(2): 31-34, dez. 2004.
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-413465

RESUMO

Este estudo procurou investigar o grau de dureza de um cimento resinoso dual cure (RelyXARC - 3M ESPE) quando polimerizado sem o contato com a luz e quando fotoativado sob três diferentes materiais restauradores indiretos (Solidex - Shofu, Empress - Ivoclar, sistema In Ceram Alumina - Vita), com dois tipos de fotopolimerizadores: luz halógena (XL 1500 - 3M) e LED - ligth emitting diode - (UltraLed - Dabi Atlante). Foram criados sete grupos experimentais: grupo SH(Solidex Halógeno), grupo SL (Solidex LED), grupo EH(Empress Halógeno), grupo EL (Empress LED), grupo IH (InCeram Alumina Halógeno), grupo IL (InCeram Alumina LED) e grupo SCL (sem contato com a luz). Pra cada grupo foram confeccionados quatro discos de cimento resinoso dual fotopolimerizados por 40 segundos, sob o material restaurador indireto, exceto para o grupo CSL onde a polimerização se deu na ausência da luz. Após uma semana, imersos em água destilada a 37°C, os discos foram submetidos ao teste de microdureza, em microdurômetro Shimadzu, com a carga de 100g, por 15 segundos para a obtenção da dureza Vickers (VHN). Os resultados foram submetidos aos testes estatísticos de ANOVA e Tukey que demonstraram uma maior dureza superficial do grupo SH em relação a todos os outros. Os grupos SL, EH, e EL não tiveram diferença estatisticamente significativa entre si, porém obtiveram valores de dureza superiores aos dos grupos IH, IL e CSL que também não mostraram diferença estatisticamente significante entre si


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Testes de Dureza
9.
RFO UPF ; 9(2): 109, 2004.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-872636

RESUMO

O presente trabalho avaliou o perfil do cirurgião-dentista formado pela faculdade de odontologia da Universidade de Passo Fundo no período de 1965 a 1999. Foi utilizado questionário para a coleta de dados. Os resultados mostraram que a maioria dos profissionais atua no estado do Rio Grande do Sul e considera necessário o aperfeiçoamento profissional. Sentem-se satisfeito com a prática da odontologia, mas deixam transparecer a insatisfação com os aspectos financeiros da profissão. Constatou-se que os cirurgiões-dentistas necessitam ampliar sua visão de atenção à saúde, percebendo o paciente como um ser integral, inserido num contexto biológico, social, econômico e cutural


Assuntos
Área de Atuação Profissional/tendências , Odontólogos , Educação em Odontologia/tendências , Prática Profissional , Faculdades de Odontologia/tendências
10.
PCL ; 5(27): 381-388, set./out. 2003. ilus, tab, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853320

RESUMO

Foram efetuadas análises de composição química, metalografia e de dureza superficial Vickers em quatro ligas metálicas comerciais à base de cobre e alumínio para uso odontológico, no estado em que são fornecidas para uso (condição comercial). Os ensaios metalográficos e de dureza foram repetidos em corpos-de-prova obtidos após terem sido submetidas as ligas a procedimentos de fundição odontológica (condição de fusão). As fundições foram efetuadas em quatro laboratórios de prótese dentária, empregando-se o processo de cera perdida, seguindo as instruções do fabricante para utilização de centrífuga comum e chama gás-oxigênio.Os ensaios metalográficos demonstram que a microestrutura das ligas estudadas no estado comercial é formada, na sua maioria, por uma região clara (provável solução dos elementos de liga no cobre-matriz). O aspecto e a homogeneidade da matriz variam de uma liga para outra. A análise metalográfica das amostras na condição de fusão evidenciou alterações microestruturais acentuadas, sendo possível destacar a presença de defeitos de fusão e de finos precipitados.Os testes de dureza superficial Vickers efetuados nas amostras na condição comercial e na condição de fusão indicam uma variação na propriedade de dureza superficial das ligas estudadas, possivelmente relacionada com a mudança microestrutural das ligas


Assuntos
Cobre , Ligas Metalo-Cerâmicas , Dureza , Materiais Biomédicos e Odontológicos
11.
Rev. Fac. Odontol. Porto Alegre ; 40(1): 57-9, set. 1999. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-283507

RESUMO

Com o propósito de contribuir com o estudo das ligas odontológicas alternativas, säo apresentados os resultados de ensaios em duas marcas comerciais de ligas a base de Ni-Cr, indicadas para trabalhos metalocerâmicos. As ligas foram analisadas nas condiçöes de venda ("condiçäo comercial") e após fusäo odontológica ("condiçäo de fusio") utilizando técnicas experimentais de metalografia, difraçäo de raio-X, dureza superficial e densidade. Os resultados da análise metalográfica e de difraçäo de raio-X mostraram que a microestrutura das ligas e marcada pela formaçäo de uma soluçäo sólida rica em Ni, matriz austenitica com estrutura cubica de fase centrada (fase y), sobre a qual se distribuem finos precipitados de fases secundárias. Os ensaios de microdureza Vickers demonstraram que as duas ligas sofrem um decrescimo dos valores de dureza superficial após submetidas a fusäo. A densidade das ligas, no entanto, se mantém praticamente inalterada


Assuntos
Ligas de Cromo/análise , Ligas Metalo-Cerâmicas , Dureza
12.
Braz. dent. j ; 9(1): 25-31, jan.-jun. 1998. ilus, tab
Artigo em Inglês | BBO - Odontologia | ID: biblio-850465

RESUMO

This study evaluated the influence of three cleaning agents on the bond strength of complete crowns cemented with zinc phosphate and polycarboxylate cements. For the polycarboxylate cement group, three cleaning agents were used: Tergentol; Tergentol + polyacrylic acid; Tergentol + citric acid. Zinc phosphate cement was used as a control group with Tergentol. There were no statistically significant differences of mean retentive force for either cement regardless of the testconditions. The marginal fit after cementation was also evaluated and the results of zinc polycarboxylayte were lower than zinc phosphate cement and were statistically significant


Assuntos
Cimentos Dentários/análise , Coroa do Dente , Cimento de Fosfato de Zinco/análise
13.
RFO UPF ; 2(1): 7-16, jan.-jun. 1997. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-211261

RESUMO

Os autores relatam um caso clínico, cirúrgico e protético de aumento de rebordo edêntulo, pela técnica do envelope preconizada por Abrams (1980), por se tratar de um defeito de Classe III, com acentuada perda de tecido bucolingual, existindo adequadas quantidade e qualidade de tecido mole na área edêntula. A desvantagem da técnica está na cicatrizaçäo aberta da área palatina doadora, o que provoca dor pós-operatória por um período prolongado


Assuntos
Humanos , Feminino , Adulto , Aumento do Rebordo Alveolar , Tecido Conjuntivo , Arcada Parcialmente Edêntula/cirurgia , Mandíbula/cirurgia , Transplante de Tecidos , Xenarthra , Reabilitação Bucal , Procedimentos Cirúrgicos Pré-Protéticos Bucais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...